Scientific Publications Search Search Author Impact Factor Release Date Research Group Search Sort by RelevanceFrom A-ZAuthored onDate/Time RangeRelease date Order AscDesc Bader, Michael Prof. Dr. (2) Edes, Inan Dr. (1) Haucke, Volker Professor (1) Heuser, Arnd Dr. (1) Hodge, Russell (3) Infante Duarte, Carmen (2) Kettenmann, Helmut Prof. Dr. (2) Klix, Sabrina (3) Mekle, Ralf (1) Millward, Jason Dr. (2) Niendorf, Thoralf Prof. Dr. (61) Paul, Friedemann Prof. Dr. med. (10) Popova, Elena Dr. (1) Poulet, James Prof. Dr. (1) Qadri, Fatimunnisa Dr. (1) Reimann, Henning Dr. (2) Siffrin, Volker (1) Starke, Ludger Benedikt (1) Todiras, Mihail (1) Uckert, Wolfgang Prof. Dr. (1) Waiczies, Helmar Dr. (8) Waiczies, Sonia PD Dr. (13) Winter, Lukas Dr. (11) Wolf, Susanne Dr. (2) (-) Ku, Min-Chi Dr. (6) (-) Münchberg, Stefanie (2) (-) Schulz-Menger, Jeanette Prof. Dr. (7) 2001 (1) 2003 (2) 2007 (3) 2008 (2) 2009 (2) 2010 (4) 2011 (1) 2012 (8) 2013 (14) (-) 2014 (6) 2015 (11) (-) 2016 (7) (-) 2017 (12) 2018 (6) 2019 (8) 2020 (9) 2021 (20) 2022 (1) 2023 (2) 2024 (1) Animal Phenotyping (1) Cardiac MRI (48) Cellular Neurosciences (3) (-) Experimental Ultrahigh-Field MR (25) From Cell States to Function (1) Magnetic Resonance (25) Molecular Biology of Peptide Hormones (2) Molecular Cardiovascular Research (1) Molecular Physiology of Somatic Sensation (1) Myology (2) Neural Circuits and Behaviour (1) Proteome Dynamics (2) Psychoneuroimmunology (1) RNA Biology and Posttranscriptional Regulation (1) Systems Biology of Gene Regulatory Elements (3) Translational Oncology of Solid Tumors (1) 25 Results: Active Filter: Ku, Min-Chi Dr.Münchberg, StefanieSchulz-Menger, Jeanette Prof. Dr.Experimental Ultrahigh-Field MR201420162017 Sort: Result score Newest to oldest Oldest to newest March 12, 2014 / PLoS ONE Rapid parametric mapping of the longitudinal relaxation time t1 using two-dimensional variable flip angle magnetic resonance imaging at 1.5 Tesla, 3 Tesla, and 7 Tesla M.A. Dieringer M. Deimling D. Santoro J. Wuerfel V.I. Madai J. Sobesky F. von Knobelsdorff-Brenkenhoff J. Schulz-Menger T. Niendorf May 01, 2014 / Invest Radiol Ophthalmic magnetic resonance imaging at 7.0 T using a 6-channel transceiver radiofrequency coil array in healthy subjects and patients with intraocular masses A. Graessl M. Muhle M. Schwerter J. Rieger C. Oezerdem D. Santoro D. Lysiak L. Winter F. Hezel S. Waiczies R.F. Guthoff K. Falke N. Hosten S. Hadlich P.C. Krueger S. Langner O. Stachs T. Niendorf August 01, 2014 / Invest Radiol Detailing the relation between renal T(2)* and renal tissue pO2 using an integrated approach of parametric magnetic resonance imaging and invasive physiological measurements A. Pohlmann K. Arakelyan J. Hentschel K. Cantow B. Flemming M. Ladwig S. Waiczies E. Seeliger T. Niendorf December 01, 2017 / Tomography Experimental MRI monitoring of renal blood volume fraction variations en route to renal magnetic resonance oximetry A. Pohlmann K. Cantow T. Huelnhagen D. Grosenick J. dos Santos Periquito L. Boehmert T. Gladytz S. Waiczies B. Flemming E. Seeliger T. Niendorf October 01, 2017 / Magn Reson Med Magnetic resonance safety and compatibility of tantalum markers used in proton beam therapy for intraocular tumors: a 7.0 Tesla study E. Oberacker K. Paul T. Huelnhagen C. Oezerdem L. Winter A. Pohlmann L. Boehmert O. Stachs J. Heufelder A. Weber M. Rehak I. Seibel T. Niendorf June 01, 2017 / Ann N Y Acad Sci Claudin peptidomimetics modulate tissue barriers for enhanced drug delivery S. Dithmer C. Staat C. Müller M.C. Ku A. Pohlmann T. Niendorf N. Gehne P. Fallier-Becker Á. Kittel F.R. Walter S. Veszelka M.A. Deli R. Blasig R.F. Haseloff I.E. Blasig L. Winkler June 01, 2017 / Circ Cardiovasc Imaging High field cardiac magnetic resonance imaging: a case for ultrahigh field cardiac magnetic resonance T. Niendorf J. Schulz-Menger K. Paul T. Huelnhagen V.A. Ferrari R. Hodge August 29, 2017 / Sci Rep Enhanced fluorine-19 MRI sensitivity using a cryogenic radiofrequency probe: technical developments and ex vivo demonstration in a mouse model of neuroinflammation S. Waiczies J.M. Millward L. Starke P.R. Delgado T. Huelnhagen C. Prinz D. Marek D. Wecker R. Wissmann S.P. Koch P. Boehm-Sturm H. Waiczies T. Niendorf A. Pohlmann June 01, 2017 / Front Phys Myocardial T(2)* mapping with ultrahigh field magnetic resonance: physics and frontier applications T. Huelnhagen K. Paul M.C. Ku T. Serradas Duarte T. Niendorf July 28, 2017 / Proc SPIE Tissue optical properties from spatially resolved reflectance: calibration and in vivo application on rat kidney T. Gladytz A. Hoppe K. Cantow B. Flemming A. Pohlmann T. Niendorf E. Seeliger D. Grosenick Pagination Current page 1 Page 2 Page 3 Next page Next › Last page Last »
March 12, 2014 / PLoS ONE Rapid parametric mapping of the longitudinal relaxation time t1 using two-dimensional variable flip angle magnetic resonance imaging at 1.5 Tesla, 3 Tesla, and 7 Tesla M.A. Dieringer M. Deimling D. Santoro J. Wuerfel V.I. Madai J. Sobesky F. von Knobelsdorff-Brenkenhoff J. Schulz-Menger T. Niendorf
May 01, 2014 / Invest Radiol Ophthalmic magnetic resonance imaging at 7.0 T using a 6-channel transceiver radiofrequency coil array in healthy subjects and patients with intraocular masses A. Graessl M. Muhle M. Schwerter J. Rieger C. Oezerdem D. Santoro D. Lysiak L. Winter F. Hezel S. Waiczies R.F. Guthoff K. Falke N. Hosten S. Hadlich P.C. Krueger S. Langner O. Stachs T. Niendorf
August 01, 2014 / Invest Radiol Detailing the relation between renal T(2)* and renal tissue pO2 using an integrated approach of parametric magnetic resonance imaging and invasive physiological measurements A. Pohlmann K. Arakelyan J. Hentschel K. Cantow B. Flemming M. Ladwig S. Waiczies E. Seeliger T. Niendorf
December 01, 2017 / Tomography Experimental MRI monitoring of renal blood volume fraction variations en route to renal magnetic resonance oximetry A. Pohlmann K. Cantow T. Huelnhagen D. Grosenick J. dos Santos Periquito L. Boehmert T. Gladytz S. Waiczies B. Flemming E. Seeliger T. Niendorf
October 01, 2017 / Magn Reson Med Magnetic resonance safety and compatibility of tantalum markers used in proton beam therapy for intraocular tumors: a 7.0 Tesla study E. Oberacker K. Paul T. Huelnhagen C. Oezerdem L. Winter A. Pohlmann L. Boehmert O. Stachs J. Heufelder A. Weber M. Rehak I. Seibel T. Niendorf
June 01, 2017 / Ann N Y Acad Sci Claudin peptidomimetics modulate tissue barriers for enhanced drug delivery S. Dithmer C. Staat C. Müller M.C. Ku A. Pohlmann T. Niendorf N. Gehne P. Fallier-Becker Á. Kittel F.R. Walter S. Veszelka M.A. Deli R. Blasig R.F. Haseloff I.E. Blasig L. Winkler
June 01, 2017 / Circ Cardiovasc Imaging High field cardiac magnetic resonance imaging: a case for ultrahigh field cardiac magnetic resonance T. Niendorf J. Schulz-Menger K. Paul T. Huelnhagen V.A. Ferrari R. Hodge
August 29, 2017 / Sci Rep Enhanced fluorine-19 MRI sensitivity using a cryogenic radiofrequency probe: technical developments and ex vivo demonstration in a mouse model of neuroinflammation S. Waiczies J.M. Millward L. Starke P.R. Delgado T. Huelnhagen C. Prinz D. Marek D. Wecker R. Wissmann S.P. Koch P. Boehm-Sturm H. Waiczies T. Niendorf A. Pohlmann
June 01, 2017 / Front Phys Myocardial T(2)* mapping with ultrahigh field magnetic resonance: physics and frontier applications T. Huelnhagen K. Paul M.C. Ku T. Serradas Duarte T. Niendorf
July 28, 2017 / Proc SPIE Tissue optical properties from spatially resolved reflectance: calibration and in vivo application on rat kidney T. Gladytz A. Hoppe K. Cantow B. Flemming A. Pohlmann T. Niendorf E. Seeliger D. Grosenick